SF6 gas comprehensive tester

Add time:2022-04-15   Number of views:564  

I. Product Overview

This product will SF6 dew point meter, SF6 purity tester, SF6 decomposition product tester into one, the original use of three instruments to achieve the function, concentrated in one instrument. One on-site measurement can complete the detection of two indicators, greatly saving the gas in the equipment. At the same time, it also reduces the workload of users and greatly improves the work efficiency.

Two, technical indicators

2.1 Main Data

(1) Measurement range

Humidity: dew point -80℃ ~ +20℃ (support PPMV and other parameters)

②SF6 decomposition products:

SO2:0 ~ 200 PPM.

H2S: 0 ~ 200ppm;

HF: 0 ~ 10ppm;

CO: 0 to 1000ppm.

③SF6 purity: 0~100%SF6 (weight ratio).

(2) Measurement accuracy

Dew point accuracy: ±0.5℃ (when the dew point temperature is lower than 0℃, the sensor output is frost point);

②SF6 decomposition products: ≤1± PPM;

③SF6 purity: ±0.5%, has nothing to do with flow.

(3) Response time

①SF6 decomposition products: 10~15 seconds;

②SF6 purity: 30 seconds.

2.2 Other Parameters

Inlet pressure: ≤ 1.0mpa;

Ambient temperature: -20~55℃;

Ambient humidity: ≤90%RH;

Charging voltage: 220VAC±10%50Hz;

Use time: the battery can work continuously for more than a few hours;

Gas consumption: 200~600mL/min;

Storage capacity: 60 pieces;

Size: 300×400×150;

Weight: 5.5kg;

Operation mode: touch key input;

Communication interface: RS232 or USB to communicate with the host computer;

Printing mode: thermosensitive Chinese word report form printing.